| Go-To Page 1 2 3 4 5 6 7 8 9 10 11 12 | Price List Back-Link ⇨
|
![]()
YL-500
![]() |
Installation method of Laser Shield Window: As any perforation and measurement processing is applicable, you can install this product snugly to any ready made equipment.
|
![]() |
Laser
absorption type. Please note that optical density graphs are based on
measurement values, not based on standard values.
| FILTER CODE | COLOR & LUMINOUS TRANS-MITTANCE (LT) |
APPLICABLE LASER | WAVE-LENGTH (nm) |
MINIMUM OPTICAL DENSITY (OD) |
MAXIMUM SIZE (mm) |
THICKNESS (mm) |
|
| COLOR | LT | ||||||
| ARGON |
ORANGE |
60% | EXCIMER | 200 ~ 514.5 | 4 < | 400 x 400 | 3.0 |
| ARGON | |||||||
| He-CD | |||||||
| Nd-YAG (SHG) |
RED |
15% | ARGON | 480 ~ 540 | 6 < | 400 x 400 | 3.0 |
| Nd-YAG (SHG) | |||||||
| LASER DIODE |
BLUE |
7% | LASER DIODE |
760 ~ 850 632.8 |
5 < | 400 x 400 | 3.0 |
| He-Ne | |||||||
| Nd-YAG |
GREEN |
25% | Nd-YAG | 1064 | 5 < | 1200 x 1000 | 3.5 |
| CO2 |
GREEN |
60% | CO2 | 10600 | 10 < | 400 x 400 | 4.0 |